Evaluation Of Doses Delivered During Ct Examinations By Different Scanners For Purposes Of Intercomparison And Dose Optimization.

dc.contributor.authorAdam, B.
dc.date.accessioned2018-02-01T12:00:51Z
dc.date.available2018-02-01T12:00:51Z
dc.date.issued2017-07
dc.descriptionThesis (MPhil)en_US
dc.description.abstractThis research study was aimed at performing dosimetry intercomparison on different CT scanners in the diagnostic radiology departments of Korle-Bu Teaching Hospital (KBTH), Sweden Ghana Medical Center (SGMC) and Global Medical and Imaging Center (GMIC).Using the standard body phantom and integrated ion chamber technique volume computed tomography dose index (CTDIvol) and Dose-Length Product (DLPs) within the phantom were evaluated. The ion chamber technique was applied to two 16 slice Siemens and one Toshiba Aquilion one CT scanners. CTDIvol and DLP values for the standard body polymethyl methacrylate ( PMMA) phantom were estimated and comparison made with corresponding console displayed values for accuracy and also to deduce a suitable method for optimization of patients and occupationally exposed worker doses. Effective doses were also calculated. An intra and inter institutional comparison of measured doses and console displayed doses were performed. Chest protocol at Automatic Exposure Control ( AEC) was applied during the scanning of the phantom. Estimated CTDIvol values (mGy) were 17mGy, 24mGy and 13.1mGy for SGMC, GMIC and KBTH respectively. These values deviated from the console displayed values by 24.1%, 22.9% and31.3% respectively. Similarly, estimated DLP values (mGy.cm) were 675mGy.cm,944mGy.cm and 419mGy.cm for SGMC, GMIC and KBTH respectively deviating from the console displayed values by 24.1%, 24.2% and 29% respectively. In terms of effective doses (E), the calculated E (mSv) values were 9.45mSv, 13.2mSv and 5.87mSv estimated from the DLPs from SGMC, GMIC and KBTH respectively using K ,the anatomy-specific dose coefficient expressing effective dose normalized to DLP in a standard CT dosimetry phantom of 0.014 mSv mGy-1 cm-1.The estimated doses were compared to other selected international Dose Reference Levels ( DRLs) and were within range.en_US
dc.identifier.urihttp://ugspace.ug.edu.gh/handle/123456789/22649
dc.language.isoenen_US
dc.publisherUniversity of Ghanaen_US
dc.subjectEvaluationen_US
dc.subjectDosesen_US
dc.subjectIntercomparisonen_US
dc.subjectDose Optimization.en_US
dc.titleEvaluation Of Doses Delivered During Ct Examinations By Different Scanners For Purposes Of Intercomparison And Dose Optimization.en_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Evaluation Of Doses Delivered During Ct Examinations By.pdf
Size:
2.64 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: