Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
Radiation Protection Dosimetry
Abstract
Organ and effective doses to 90 patients undergoing some selected fluoroscopic examinations at the Korle-Bu Teaching Hospital were estimated using the Monte Carlo-based program (PCXMC version 1.5). Radiation dose was estimated from free-in-air measurements. The mean effective doses were found to be 0.29 ± 0.07, 0.84 ± 0.13, 3.15 ± 0.44, 6.24 ± 0.70 and 0.38 ± 0.05 mSv for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. The dose area product was estimated to be 3.55 ± 0.95, 16.44 ± 2.60, 50.81 ± 7.04, 99.69 ± 10.85 and 9.32 ± 0.99 Gy cm2 > for urethrogram, barium swallow, barium meal, barium enema and myelogram examinations, respectively. Optimisation of procedures is required for barium enema and barium meal examinations. © The Author 2009. Published by Oxford University Press. All rights reserved.