Diagnostic accuracy of a novel tuberculosis point-of-care urine lipoarabinomannan assay for people living with HIV: A meta-analysis of individual in- and outpatient data
| dc.contributor.author | Opintan, J. | |
| dc.contributor.author | Broger, T. | |
| dc.contributor.author | Nicol, M.P. | |
| dc.contributor.author | Szekely, R. | |
| dc.contributor.author | Bjerrum, S. | |
| dc.contributor.author | Sossen, B. | |
| dc.contributor.author | Schutz, C. | |
| dc.contributor.author | Johansen, I.S. | |
| dc.contributor.author | Mitarai, S. | |
| dc.contributor.author | ChikamatsuI, K. | |
| dc.contributor.author | Kerkhoff, A.D. | |
| dc.contributor.author | Mace´, A. | |
| dc.contributor.author | Ongarello, S. | |
| dc.contributor.author | Meintjes, G. | |
| dc.contributor.author | Denkinger, C.M. | |
| dc.contributor.author | Schumacher, S.G. | |
| dc.date.accessioned | 2020-07-13T10:10:12Z | |
| dc.date.available | 2020-07-13T10:10:12Z | |
| dc.date.issued | 2020-05-01 | |
| dc.description | Research Article | en_US |
| dc.description.abstract | Background Tuberculosis (TB) is the most common cause of death in people living with HIV (PLHIV), yet TB often goes undiagnosed since many patients are not able to produce a sputum specimen, and traditional diagnostics are costly or unavailable. A novel, rapid lateral flow assay, Fujifilm SILVAMP TB LAM (SILVAMP-LAM), detects the presence of TB lipoarabinomannan (LAM) in urine, and is substantially more sensitive for diagnosing TB in PLHIV than an earlier LAM assay (Alere Determine TB LAM lateral flow assay [LF-LAM]). Here, we present an individual participant data meta-analysis of the diagnostic accuracy of SILVAMP-LAM in adult PLHIV, including both published and unpublished data. Methods and findings Adult PLHIV (≥18 years) were assessed in 5 prospective cohort studies in South Africa (3 cohorts), Vietnam, and Ghana, carried out during 2012 to 2017. Of the 1,595 PLHIV who met eligibility criteria, the majority (61%) were inpatients, median age was 37 years (IQR 30–43), 43% had a CD4 count ≤ 100 cells/μl, and 35% were receiving antiretroviral therapy. Most participants (94%) had a positive WHO symptom screen for TB on enrollment, and 45% were diagnosed with microbiologically confirmed TB, using mycobacterial culture or Xpert MTB/RIF testing of sputum, urine, or blood. Previously published data from inpatients were combined with unpublished data from outpatients. Biobanked urine samples were tested, using blinded double reading, with SILVAMP-LAM and LF-LAM. Applying a microbiological reference standard for assessment of sensitivity, the overall sensitivity for TB detection was 70.7% (95% CI 59.0%–80.8%) for SILVAMP-LAM compared to 34.9% (95% CI 19.5%–50.9%) for LF-LAM. Using a composite reference standard (which included patients with both microbiologically confirmed as well as clinically diagnosed TB), SILVAMP-LAM sensitivity was 65.8% (95% CI 55.9%–74.6%), and that of LF-LAM 31.4% (95% CI 19.1%–43.7%). In patients with CD4 count ≤ 100 cells/μl, SILVAMP-LAM sensitivity was 87.1% (95% CI 79.3%–93.6%), compared to 56.0% (95% CI 43.9%–64.9%) for LF-LAM. In patients with CD4 count 101–200 cells/μl, SILVAMP-LAM sensitivity was 62.7% (95% CI 52.4%–71.9%), compared to 25.3% (95% CI 15.8%–34.9%) for LF-LAM. In those with CD4 count > 200 cells/μl, SILVAMP-LAM sensitivity was 43.9% (95% CI 34.3%–53.9%), compared to 10.9% (95% CI 5.2%–18.4%) for LF-LAM. Using a microbiological reference standard, the specificity of SILVAMP-LAM was 90.9% (95% CI 87.2%–93.7%), and that of LF-LAM 95.3% (95% CI 92.2%–97.7%). Limitations of this study include the use of biobanked, rather than fresh urine samples, and testing by skilled laboratory technicians in research laboratories, rather than at the point of care. Conclusions In this study, we found that SILVAMP-LAM identified a substantially higher proportion of TB patients in PLHIV than LF-LAM. The sensitivity of SILVAMP-LAM was highest in patients with CD4 count ≤ 100 cells/μl. Further work is needed to demonstrate accuracy when implemented as a point-of-care test. | en_US |
| dc.description.sponsorship | This work was funded by the Global Health Innovative Technology (GHIT) Fund (grant number G2017-207), the UK Department for International Development (DFID) (grant number 300341-102), the Dutch Ministry of Foreign Affairs (grant number PDP15CH14), the Bill & Melinda Gates Foundation (grant number OPP1105925), the Australian Department of Foreign Affairs and Trade (grant number 70957) and the German Federal Ministry of Education and Research (BMBF; grant number 2020 62 156). The Cohort2 study was funded by the Wellcome Trust (088590 and 085251). GM was supported by Wellcome Trust (098316 and 203135/Z/16/Z), the South African Research Chairs Initiative of the Department of Science and Technology and the National Research Foundation (NRF) of South Africa (Grant No 64787), NRF incentive funding (UID: 85858) and the South African Medical Research Council through its TB and HIV Collaborating Centres Programme, with funds received from the National Department of Health (RFA#SAMRC-RFA-CC:TB/HIV/AIDS-01-2014). CS received funding from the South African Medical Research Council through the National Health Scholarship Programme. ADK received funding from the National Institute of Allergy and Infectious Diseases (Grant No T32 AI060530). BS received salary support from the Wellcome Trust (grant number 088316). CMD is supported by a fellowship of the Burroughs–Wellcome Fund from the American Society of Tropical Medicine and Hygiene. | en_US |
| dc.identifier.citation | Broger T, Nicol MP, Sze´kely R, Bjerrum S, Sossen B, Schutz C, et al. (2020) Diagnostic accuracy of a novel tuberculosis point-of-care urine lipoarabinomannan assay for people living with HIV: A meta-analysis of individual in- and outpatient data. PLoS Med 17(5): e1003113. https://doi.org/10.1371/journal.pmed.1003113 | en_US |
| dc.identifier.other | https://doi.org/10.1371/journal.pmed.1003113 | |
| dc.identifier.uri | http://ugspace.ug.edu.gh/handle/123456789/35553 | |
| dc.language.iso | en | en_US |
| dc.publisher | PLOS MEDICINE | en_US |
| dc.relation.ispartofseries | 17;5 | |
| dc.subject | Tuberculosis (TB) | en_US |
| dc.subject | HIV (PLHIV) | en_US |
| dc.subject | (SILVAMP-LAM) | en_US |
| dc.subject | laboratory technicians | en_US |
| dc.title | Diagnostic accuracy of a novel tuberculosis point-of-care urine lipoarabinomannan assay for people living with HIV: A meta-analysis of individual in- and outpatient data | en_US |
| dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Diagnostic-accuracy-of-a-novel-tuberculosis-pointofcare-urine-lipoarabinomannan-assay-for-people-living-with-HIV-A-metaanalysis-of-individual-in-and-outpatient-dataPLoS-medicine.pdf
- Size:
- 1.81 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.6 KB
- Format:
- Item-specific license agreed upon to submission
- Description:
