dc.description.abstract | A conducting polymer-based composite material of poly(3,4-ethylenedioxythiophene) (PEDOT): poly(4-styrenesulfonate) (PSS) doped with different percentages of a room temperature ionic liquid (IL), 1-ethyl-3-methylimidazolium tetrafluoroborate ([EMIM][BF4]), was prepared and a very small amount of the composite (2.0 µL) was drop-coated on the working area of a screen-printed carbon electrode (SPCE). The SPCE, modified with PEDOT:PSS/IL composite thin-film, was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), profilometry and sessile contact angle measurements. The prepared PEDOT:PSS/IL composite thin-film exhibited a nano-porous microstructure and was found to be highly stable and conductive with enhanced electrocatalytic properties towards catechol, a priority pollutant. The linear working range for catechol was found to be 0.1 µM–330.0 µM with a sensitivity of 18.2 mA·mM·cm−2 and a calculated limit of detection (based on 3× the baseline noise) of 23.7 µM. When the PEDOT:PSS/IL/SPCE sensor was used in conjunction with amperometry in stirred solution for the analysis of natural water samples, the precision values obtained on spiked samples (20.0 µM catechol added) (n = 3) were 0.18% and 0.32%, respectively, with recovery values that were well over 99.0%. © 2017 by the authors. Licensee MDPI, Basel, Switzerland. | en_US |
dc.identifier.other | vol.17(8) | |
dc.identifier.other | DOI:10.3390/s17081716 | |
dc.identifier.uri | http://ugspace.ug.edu.gh/handle/123456789/31627 | |
dc.language.iso | en | en_US |
dc.publisher | Sensors (Switzerland) | en_US |
dc.subject | Amperometric sensors; Angle measurement; Carbon; Conducting polymers; Contact angle; Cyclic voltammetry; Electrochemical electrodes; Electrochemical impedance spectroscopy; Electrodes; Film preparation; Ionic liquids; Liquids; Nanocomposites; Phenols; Scanning electron microscopy; Spectroscopy; Thin films; Disposable sensors; Hexacyanoferrates; PEDOT:PSS; Room temperature ionic liquids; Screen printed electrodes; Nanocomposite films | en_US |
dc.title | A disposable amperometric sensor based on high-performance PEDOT:PSS/Ionic liquid nanocomposite thin film-modified screen-printed electrode for the analysis of catechol in natural water samples | en_US |
dc.type | Article | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- A Disposable Amperometric Sensor Based on High- Performamce PEDOT; PSS Ionic Liquid Nanocomposite Thin Film- Modifified.pdf
- Size:
- 2.4 MB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1
Loading...
- Name:
- license.txt
- Size:
- 1.6 KB
- Format:
- Item-specific license agreed upon to submission
- Description: