A disposable amperometric sensor based on high-performance PEDOT:PSS/Ionic liquid nanocomposite thin film-modified screen-printed electrode for the analysis of catechol in natural water samples

dc.contributor.authorKrampa, F.D.
dc.contributor.authorAniweh, Y.
dc.contributor.authorAwandare, G.A.
dc.contributor.authorKanyong, P.
dc.date.accessioned2019-07-22T16:37:25Z
dc.date.available2019-07-22T16:37:25Z
dc.date.issued2017
dc.description.abstractA conducting polymer-based composite material of poly(3,4-ethylenedioxythiophene) (PEDOT): poly(4-styrenesulfonate) (PSS) doped with different percentages of a room temperature ionic liquid (IL), 1-ethyl-3-methylimidazolium tetrafluoroborate ([EMIM][BF4]), was prepared and a very small amount of the composite (2.0 µL) was drop-coated on the working area of a screen-printed carbon electrode (SPCE). The SPCE, modified with PEDOT:PSS/IL composite thin-film, was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM), profilometry and sessile contact angle measurements. The prepared PEDOT:PSS/IL composite thin-film exhibited a nano-porous microstructure and was found to be highly stable and conductive with enhanced electrocatalytic properties towards catechol, a priority pollutant. The linear working range for catechol was found to be 0.1 µM–330.0 µM with a sensitivity of 18.2 mA·mM·cm−2 and a calculated limit of detection (based on 3× the baseline noise) of 23.7 µM. When the PEDOT:PSS/IL/SPCE sensor was used in conjunction with amperometry in stirred solution for the analysis of natural water samples, the precision values obtained on spiked samples (20.0 µM catechol added) (n = 3) were 0.18% and 0.32%, respectively, with recovery values that were well over 99.0%. © 2017 by the authors. Licensee MDPI, Basel, Switzerland.en_US
dc.identifier.othervol.17(8)
dc.identifier.otherDOI:10.3390/s17081716
dc.identifier.urihttp://ugspace.ug.edu.gh/handle/123456789/31627
dc.language.isoenen_US
dc.publisherSensors (Switzerland)en_US
dc.subjectAmperometric sensors; Angle measurement; Carbon; Conducting polymers; Contact angle; Cyclic voltammetry; Electrochemical electrodes; Electrochemical impedance spectroscopy; Electrodes; Film preparation; Ionic liquids; Liquids; Nanocomposites; Phenols; Scanning electron microscopy; Spectroscopy; Thin films; Disposable sensors; Hexacyanoferrates; PEDOT:PSS; Room temperature ionic liquids; Screen printed electrodes; Nanocomposite filmsen_US
dc.titleA disposable amperometric sensor based on high-performance PEDOT:PSS/Ionic liquid nanocomposite thin film-modified screen-printed electrode for the analysis of catechol in natural water samplesen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A Disposable Amperometric Sensor Based on High- Performamce PEDOT; PSS Ionic Liquid Nanocomposite Thin Film- Modifified.pdf
Size:
2.4 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.6 KB
Format:
Item-specific license agreed upon to submission
Description: