Calibration of High Dose Rate Cobalt-60 Source Using a Farmer Type Chamber in A Locally Constructed Hollow Phantom
dc.contributor.author | Kambauwa, J.D | |
dc.date.accessioned | 2016-11-03T13:41:13Z | |
dc.date.accessioned | 2017-10-13T17:44:33Z | |
dc.date.available | 2016-11-03T13:41:13Z | |
dc.date.available | 2017-10-13T17:44:33Z | |
dc.date.issued | 2015 | |
dc.description.abstract | An important aspect of general quality assurance program for brachytherapy dosimetry is source calibration.Vendors assign large uncertainities of up to ±10 % for the stated source calibrated values. It is thus important to check the vendor stated calibration. There are three main methods of calibrating brachytherapy sources and they are the “Free- in – air” method, using a re-entrant( well ) type chamber and using a thimble (Farmer) type ionization chamber in a phantom. The main objective of this study was to compare values of source strength obtained by using the re-entrant chamber method and the thimble (farmer) type ionization chamber in a phantom method. A cylindrical hollow phantom was constructed from Poly methyl methacrylate (PMMA) having four holes located at a distance of 8cm from the centre and the angle between each of the holes being 90° from the centrally located source holder . The experimental set up followed International Atomic Energy Agency (IAEA) Technical Document 1274 (IAEA-TECDOC-1274) for the re-entrant chamber method and DIN 68909-2 in combination with DGMP report 13 for the thimble ionization chamber in a phantom method. Measurements carried out using the well type chamber deviated from the theoretical value of the source by -1.36% whereas those measured by the Farmer type ionization chamber in a locally constructed phantom deviated from the theoretical air kerma strength value by -2.1%. The difference in measured values from the two measuring methods was found to be0.8%. | en_US |
dc.identifier.uri | http://197.255.68.203/handle/123456789/8886 | |
dc.language.iso | en | en_US |
dc.publisher | University of Ghana | en_US |
dc.subject | CALIBRATION | en_US |
dc.subject | HIGH DOSE | en_US |
dc.subject | COBALT-60 | en_US |
dc.subject | SOURCE | en_US |
dc.subject | FARMER | en_US |
dc.subject | CHAMBER | en_US |
dc.subject | LOCALLY CONSTRUCTED | en_US |
dc.subject | HOLLOW PHANTOM | en_US |
dc.title | Calibration of High Dose Rate Cobalt-60 Source Using a Farmer Type Chamber in A Locally Constructed Hollow Phantom | en_US |
dc.type | Thesis | en_US |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Calibration of High Dose Rate Cobalt-60 Source Using a Farmer Type Chamber in A Locally Constructed Hollow Phantom - 2015.pdf
- Size:
- 6.65 MB
- Format:
- Adobe Portable Document Format